Biến tần QMA Q5000, Biến tần QMA Q-5000, Bien tan QMA Q-5000, Biến tần QMA Q5000, Bán biến tần QMA Q-5000, Sửa biến tần QMA
Biến tần QMA Q-5000
Sơ đồ đấu nối Biến tần QMA Q-5000
>>> DOWNLOAD HƯỚNG DẪN SỬ DỤNG BIẾN TẦN QMA Q-5000
[INTRODUCTION]
Q-5000 SERIES Hi-Performance Low-noise Mini Vector Inverter is a new-type mini-AC inverter but packed with high performance features for induction motors available from 0.4-2.2kw which is the ideal solution to variable speed.
Q-5000 is featured for SPWM design which provides low noise and high start torque. The inverter is independent and used in 50/60Hz (±5% fluctuation is allowable). The current overload rating is 150% for 60 seconds, sensorless vector control and V/F control make this inverter more brilliant for most general applications.
Q5000 is feature-packed, low cost and compact. The high-speed current limiting function minimizes over-current trips. Inrush current suppression plus grounding protection are built in for safe and trip free operation.
Q-5000 is innovative design features; the digital operator includes a 3-digit LED status display. The multi-speed step function (7 pre-set speeds) and 4 acceleration/deceleration time make it ideal for food processing and its smooth speed variation can bring energy savings in fan and pump operation.
Q-5000 also have multi-function I/O terminals, 0-10V, 4-20mA inputs and analog output, plus lip compensation, over torque detection and high speed search which all make this highly specified inverter a particular versatile inverter.
RS-485 Modbus serial communication port supports net work which is convenient for variety of host link allowing 32 nodes on a single net work.
Q-5000 is proficient for conveyors, grinders, centrifuges, pumps, fans, and blowers used in material handling, packaging, food processing, and commercial laundry etc.
Q-5000 is a perfect choice for high performance and low cost. Trust it for your success.
[FEATURES]
*Without PG Vector Control (SVC), V/F control.
*Fulfill high torque and failure-free operation from a 1% low speed.
*Carrier frequency reaches 15 kHz.
*Built-in PID, multiple protective functions, safe and guaranteed.
*Potentiometer for frequency regulation is configured as standard.
*Automatic energy-efficient enables the motor to run in a high-efficiency and energy-saving way.
*RS-485 communication interface and standard MODBUS communication protocol are adopted.
*No metallic sound as that of other inverters and ultra-low noise.
*Powerful dynamic and static autotuning functions.
[SPECIFICATIONS]
230V Class
Model Q5000-XXX-2XX
|
004
|
007
|
015
|
022
|
|
Motor rated output power (KW)
|
0.4
|
0.75
|
1.5
|
2.2
|
|
Motor rated output power (HP)
|
0.5
|
1.0
|
2.0
|
3.0
|
|
Output
|
Rated output capacity (KVA)
|
1.0
|
1.9
|
2.7
|
3.8
|
Rated output current (A)
|
2.5
|
5.0
|
6.5
|
11
|
|
Max. output voltage (V)
|
Corresponding to the input voltage
|
||||
Max. output frequency (Hz)
|
0.1~400Hz
|
||||
Unit weight kg/Unit
|
1.5
|
1.5
|
1.5
|
1.5
|
|
Power supply
|
Rated input current (A)
|
6.3/2.9
|
11.5/7.6
|
15.7/8.8
|
12.5
|
Single-phase unit with 3-phase input current
|
3.2
|
6.3
|
9.0
|
–
|
|
Allowable voltage variable range
|
Single/three phase power
|
3-phase
|
|||
180~264VAC
|
|||||
Allowable frequency variable
|
50/60Hz ± 5%
|
Model Q5000- XXX-43X
|
004
|
007
|
015
|
022
|
|
Motor rated output power (KW)
|
0.4
|
0.75
|
1.5
|
2.2
|
|
Motor rated output power (HP)
|
0.5
|
1.0
|
2.0
|
3.0
|
|
Output
|
Rated output capacity (KVA)
|
1.0
|
2.3
|
3.1
|
3.8
|
Rated output current (A)
|
2.0
|
3.0
|
4.2
|
5.5
|
|
Max. output voltage (V)
|
Corresponding to the input voltage
|
||||
Max. output frequency (Hz)
|
0.1~400Hz
|
||||
Unit weight kg/Unit
|
1.5
|
1.5
|
1.5
|
1.5
|
|
Power supply
|
Rated input current (A)
|
2.5
|
4.2
|
5.7
|
6.0
|
Single-phase unit with 3-phase input current
|
–
|
–
|
–
|
–
|
|
Allowable voltage variable range
|
3-phase power
|
||||
342~528VAC
|
|||||
Allowable frequency variable
|
50/60Hz ± 5%
|
Control characteristics
|
Control methods
|
SPWM mode of sinusoidal wave (carrier frequency 1KHz~15KHz)/(Sensorless Vector Control)
|
|||
Output frequency resolution
|
0.1Hz
|
||||
Torque characteristics
|
Torque compensation and slip compensation. Starting torque can be more than 150% in 0.5Hz.
|
||||
Overload tolerance
|
150% of rated output current for 1 min.
|
||||
Accel/decel time
|
0.1~600s (can be set individually)
|
||||
V/F curve
|
Any V/F curve setting
|
||||
Stalling prevention
|
Set as rated current percentage, 50~200%
|
||||
Operation characteristics
|
Frequency setting signal
|
Digital operator
|
Set by
|
||
External signal
|
Potentiometer 5KΩ/0.5W, DC0~+10V (input impedance 47 KΩ) 4~20mA (output impedance 250 KΩ), serial communication RS485 multi-function input options 1~5 (7 bands speed, inching, up/down commands)
|
||||
Operation setting signal
|
Digital operator
|
Set by RUN and STOP keys
|
|||
External signal
|
Multi-function operation mode,
serial communication MODBUS (RS485)
|
||||
Multi-function input signal
|
Multi-band speed command 1~7 options, inching command, acceleration/deceleration prohibition command, first/acceleration and deceleration switching command, counter, programmable operation, external B.B, first/second frequency source option, increase/decrease frequency terminal setting
|
||||
Multi-function output signal
|
In operation, operating frequency reach, set frequency reach, zero speed, in B.B, faults indication, Local/Remote indication, counting value reach indication, programmable operation
|
||||
Analog output signal
|
Analog frequency/current signal output
|
||||
Other functions
|
Carrier frequency regulation, s curve, abnormal record checking, acceleration/deceleration auto regulation, over-current stall prevention, over-voltage stall prevention, reverse prohibition setting AVR function, reboot after momentary power loss, parameter lock/reset, power-efficient operation, PID feedback control, DC braking initial frequency setting, frequency upper and lower limit setting, serial communication RS485, DC braking, sleep/wake function, simple positioning function
|
||||
Protection functions
|
Over-voltage, over-current, low voltage, overload limitation, electronic heating relay, overheat self measuring, grounding protection, faults contacts.
|
||||
Cooling methods
|
Forced air cooling
|
||||
Environment
|
Service site
|
With height below 1000m, indoor (no corrosive gas, liquid and dust)
|
|||
Ambient temperature
|
-10℃~50℃ (no condensation or frost)
|
||||
Storage temperature
|
-20℃~60℃
|
||||
Humidity
|
Below 90%RH (no condensation)
|
||||
Vibration
|
Below 20Hz 9.80665m/s2 (1G)~50Hz 5.88m/s2 (0.6G)
|
||||
Remark: 3-phase unit can not be input by single-phase power, otherwise, the service life and the characteristics of the inverter will be affected.
|